FAQs

What are Phoenix battery safes designed for?

Phoenix battery safes are purpose-built for the storage and charging of lithium-ion batteries. They are not general-purpose storage cabinets — every element of the design, from the double-wall steel construction to the ventilation system and integrated smoke detection, is specifically engineered to manage the risks associated with lithium battery storage and charging.

The primary hazard they address is thermal runaway — a chain reaction within a lithium cell that can produce extreme heat, fire, and toxic gases within seconds. A Phoenix battery safe contains a thermal event if one occurs, significantly reducing the risk to people, property, and surrounding infrastructure.

Any industry that regularly stores or charges lithium-ion batteries may need a dedicated battery safe. In Australia, common sectors include mining and resources, construction and civil works, logistics and warehousing, manufacturing, government and defence, councils and local government, schools and educational institutions, healthcare and aged care, and commercial fleet operators managing e-bikes or electric vehicles. Residential and small business customers may also need a safe for workshops, garages and trade environments. For current supply, we provide the Phoenix BS1940 Commander Pro; contact us to confirm the suitable size and obtain a quote.

We supply the Phoenix BS1940 Commander Pro only, certified to VDMA 24994:2024-08 / ECB·S. The range comprises six sizes, BS1941–BS1946, with capacities from 2,500 Wh to 22,500 Wh. BS1941, BS1942 and BS1944 are typically special order with a 6–10 week lead time; BS1943, BS1945 and BS1946 are held where stock or display availability allows. Please contact us for current availability and a quote. Titan, Fighter and Commander models are discontinued or unavailable and are not recommended as current products.

VDMA 24994:2024-08 is the world’s first independently verified test standard specifically for lithium battery storage and charging cabinets. It was developed through collaboration between Phoenix and the ESSA/ECB·S battery safe working group and finalised in August 2024.

Certification requires independent testing by ECB·S against defined criteria covering fire resistance, containment performance, ventilation, and electrical safety. It is not a self-declared standard — every certified unit has been independently tested and verified. In our current range, this certification applies to the Phoenix BS1940 Commander Pro only.

In Australia, where no equivalent national standard currently exists for this product category, specifying a VDMA 24994 certified unit is the clearest way to demonstrate due diligence under WHS legislation. It gives your organisation a defensible position in the event of an incident, insurance claim, or WorkSafe audit. Battery Safes Australia can provide a copy of the VDMA certificate for BS1940 Commander Pro procurement documentation on request.

  • Yes — and this is the recommended approach. All Phoenix battery safes include built-in power outlets specifically to allow charging to occur safely inside the cabinet. Charging inside a dedicated, ventilated, fire-rated safe is significantly safer than charging on open benches, floors, or in storage areas.

    The ventilation system is designed to manage heat and gases produced during normal charging. The integrated smoke detector provides early warning if something goes wrong. Charging inside the safe keeps any potential incident contained within the cabinet rather than allowing it to spread.

Phoenix battery safes are designed with integrated heat-protected ventilation as a standard feature. The ventilation system manages heat and off-gases produced during charging and helps prevent heat build-up within the cabinet.

You do not need to install additional external ventilation for the safe itself — the integrated system handles this. However, if you are placing a safe in a very small, enclosed room or space, we recommend consulting with us about the installation environment to ensure adequate airflow around the unit.

Battery safes are fire-rated, not fireproof. The distinction matters. A fire-rated cabinet is tested and certified to resist fire and contain a thermal event for a defined period. The Phoenix BS1940 Commander Pro is fire-rated with 90-minute fire protection. This means the cabinet is designed to contain a battery fire and prevent it from spreading to surrounding materials for that period, giving time for evacuation and emergency response. No cabinet can guarantee total prevention of fire if a major thermal runaway event occurs. What a certified battery safe does is significantly reduce the risk of fire spreading, buy critical time for emergency response, and demonstrate genuine due diligence to WorkSafe inspectors and insurers.

Our current range is the Phoenix BS1940 Commander Pro only, available in six sizes, BS1941–BS1946. Capacities range from 2,500 Wh to 22,500 Wh. BS1941, BS1942 and BS1944 are typically special order with a 6–10 week lead time; BS1943, BS1945 and BS1946 are held where stock or display availability allows. Contact us with the battery type, quantity and Wh rating for sizing advice and a quote.

The safes are designed for straightforward installation. Anchoring to a concrete floor is the standard method and can be completed by a competent tradesperson following the supplied installation guide. Professional installation is not mandatory, but we recommend it for larger BS1940 Commander Pro units. Battery Safes Australia can advise on installation requirements and connect you with suitable installers in your area. Contact us to discuss your location and site requirements before ordering, particularly if freight access or floor preparation may be a consideration.

The safe is designed to contain the event. If thermal runaway occurs inside the cabinet, the double-wall steel construction, fire-rated lining, and controlled ventilation work together to prevent the fire from spreading beyond the cabinet. The integrated smoke detector and alarm activate to alert people in the area. In the event of a fire, do not open the safe door — this can introduce oxygen and escalate the event. Evacuate the area and contact emergency services. The Phoenix BS1940 Commander Pro includes a plinth for safe relocation of the unit in an emergency if required. After any thermal event, the safe should be inspected before further use. Contact Battery Safes Australia for guidance on post-incident procedures.

Choose the Phoenix BS1940 Commander Pro based on your use case, the total Wh of the batteries you store or charge, and the available space and operating environment, including access, ventilation and site requirements. The six BS1940 sizes, BS1941–BS1946, cover 2,500 Wh to 22,500 Wh. VDMA 24994:2024-08 / ECB-S certification matters when you need independently tested documentation for procurement, insurer, WHS or compliance requirements. BS1941, BS1942 and BS1944 are typically special order with a 6-10 week lead time; BS1943, BS1945 and BS1946 are held where stock or display availability allows. Contact Battery Safes Australia for sizing advice and a quote.

Australia does not currently mandate a single national standard specifically for lithium battery storage cabinets. However, WHS legislation across all states and territories requires businesses to identify and manage workplace hazards — and uncontrolled lithium battery storage and charging is an increasingly recognised hazard.

WorkSafe authorities, insurers, and procurement teams are increasingly referencing VDMA 24994:2024-08 as the relevant benchmark when assessing battery storage solutions. Specifying a purpose-built, certified product is the most defensible position under the general duty of care obligations in Australian WHS law. Battery Safes Australia can provide compliance documentation and specification sheets to support your procurement or audit process.

Phoenix battery safes require minimal routine maintenance. We recommend a monthly visual inspection of the cabinet exterior, door seals, and locking mechanism. The smoke detector should be tested regularly in accordance with the manufacturer’s guidelines — typically monthly. Power outlet connections inside the cabinet should be checked periodically to ensure they are secure and undamaged.

The ventilation system should be checked to ensure it is clear of obstruction. If the safe has been subjected to a thermal event or significant physical impact, it should be inspected by a qualified technician before further use.

Contact Battery Safes Australia for spare parts, service support, or any concerns about the condition of your unit.

Still have a question?

Contact Battery Safes Australia directly — we're happy to help with product selection, compliance documentation, pricing, or any technical questions about our range.

Shopping cart

close